Fitur konverter frekuensi listrik

Fungsi Khusus:
- Khusus untuk Pasokan Air, Fungsi Lengkap
- Instalasi kabinet, pengembangan yang kuat
- Dapat mewujudkan mode kontrol rotasi satu-ke-dua
Kinerja yang andal:
- Pastikan operasi produk yang andal jangka panjang
- Kontrol kualitas profesional memastikan kualitas produk
- Desain saluran udara independen, desain kenaikan suhu standar
- Komponen inti merek, solusi teknis canggih
Perlindungan Sempurna:
- Peralatan berlebihan, tegangan berlebih, terlalu panas, perlindungan sirkuit pendek
- Output Motor Perlindungan Sirkuit Pendek
- Tekanan Air Tekanan Tinggi, Tekanan Rendah, Kekurangan Air Idling, Perlindungan Antibeku
- Fungsi reset kekurangan air
Ekspansi Fleksibel:
- Komunikasi Dual-Channel Standar
- Relay Dual-Channel Standar
- Kontrol multi-link dan pemantauan komputer host
Karakteristik kontrol
- Mode Kontrol: Kontrol V/F
- Torsi mulai: 1Hz 100%
- Kisaran Penyesuaian Kecepatan: 1:20
- Akurasi Kecepatan: ± 1. 0%
- Frekuensi operator: 0. 5KHz ~ 16KHz
- Kapasitas Overload: 150% Nilai Arus untuk 60 -an, 180 Nilai Arus untuk 1S
Kontrol gerak
- Tegangan input: 220V/380V; Kisaran fluktuasi: ± 15%
- Frekuensi input: 50/60Hz, kisaran fluktuasi: ± 5%
- Voltage output: 0- Input tegangan, kesalahan kurang dari 5%
- Frekuensi output: v/f: 0-100 hz
- Saluran Perintah Operasi: 3 Saluran: Panel Operasi Diberikan, Terminal Kontrol Diberikan, Port Komunikasi Serial Diberikan, dapat dialihkan dengan berbagai cara
- Sumber frekuensi: pengaturan data, pengaturan potensiometer pulsa panel, pengaturan tegangan analog, pengaturan arus analog, pengaturan komunikasi serial, dll. Dapat diaktifkan dengan berbagai cara
- Catu Daya Analog: 5V/10V/24V Tiga tegangan catu daya, gunakan sebagian besar sensor
- Terminal Input: 2 Terminal Input Digital; 1 terminal input modul; 2 output relai; 2 Antarmuka Komunikasi
Fungsi dasar

- PID bawaan: dapat dengan mudah mewujudkan sistem kontrol loop tertutup
- Fungsi AVR: Ketika tegangan jaringan berubah, ia dapat secara otomatis menjaga agar tegangan output konstan
- Kerugian tegangan dan kelebihan yang berlebihan: Secara otomatis membatasi arus dan tegangan selama operasi untuk mencegah arus berlebih dan tegangan berlebih tersandung
- Fungsi pembatasan arus cepat: Meminimalkan kesalahan arus berlebih dan meningkatkan stabilitas sistem
- Power-on Periferal Equipment Keselamatan Self-check: Dapat mewujudkan deteksi keselamatan peralatan periferal bertenaga seperti grounding, sirkuit pendek, dll.
- Fungsi Mulai Otomatis Power-On: Power-on Automatic Start adalah opsional, Mulai Delay dapat disesuaikan.
- Fungsi pasokan air satu-ke-dua:Melalui kerja sama perangkat lunak dan relay, fungsi satu mesin yang mengendarai dua pompa dapat direalisasikan
- Operasi hemat energi otomatis:Secara otomatis mengurangi tegangan output di bawah beban ringan untuk mencapai efek penghematan energi
- Fungsi Kontrol Tekanan Konstan:Penyesuaian PID, pemeriksaan pemutusan umpan balik PID, tidur PID dan bangun
- Fungsi antibeku:Frekuensi, waktu, dan siklus dapat diatur untuk kontrol fungsi antibeku
- Deteksi kebocoran air:Mengoptimalkan kontrol tidur melalui koefisien deteksi kebocoran air
Tampilan dan Operasi Keyboard
- Tampilan LED: Dapat menampilkan tekanan umpan balik, tekanan target, frekuensi operasi, arus operasi dan data lainnya
- Fungsi kunci parameter: Tentukan apakah parameter terkunci dalam keadaan berjalan atau shutdown untuk mencegah kesalahan operasi
Lingkungan penggunaan
- Tempat penggunaan: Di dalam ruangan, jauh dari sinar matahari langsung, debu, gas korosif, gas yang mudah terbakar, kabut minyak, uap air, air yang menetes atau garam, dll.
- Ketinggian: di bawah 1000m; Di atas 1000m, gunakan dengan Derating, 1% untuk setiap peningkatan 100m
- Suhu sekitar: -10 derajat ~ 40 derajat, Diperlukan Derating ketika suhu melebihi 40, 1% untuk setiap peningkatan 1% dalam suhu sekitar, suhu sekitar maksimum adalah 50 derajat
- Kelembaban: 95%RH, hindari kondensasi
- Getaran: akselerasi getaran kurang dari 0. 6g
- Suhu penyimpanan: -25 derajat ~ +60 derajat
Deskripsi Panel Operasi

- MENU: Digunakan untuk beralih dari model tetap ke model modifikasi.
- P.sp/ent: Kunci Pintasan Pengaturan Tekanan Air dan Pengaturan Kunci Parameter "Konfirmasi".
- MENGGESER: Digunakan untuk menggeser tampilan dan memindahkan kursor dalam modifikasi parameter. Dalam status berjalan, menekan "shift" dapat beralih bolak -balik di antara frekuensi berjalan, arus output, pengaturan tekanan dan tekanan umpan balik. Tekan "Shift" untuk memodifikasi parameter. Bit flicker adalah bit saat ini yang dapat dimodifikasi.
- ▲ ▼ kunci: digunakan untuk memodifikasi nilai parameter.
- BERLARI: Mulai tombol saat menggunakan keyboard sebagai mode awal.
- BERHENTI: Stop Tombol dan tombol reset kesalahan saat menggunakan keyboard sebagai mode start.
- Jop: Digunakan dalam tahap debugging VFD, mesin tambahan dapat berjalan secara independen.
- Tombol: Putar ke kenop untuk mengubah tekanan pengaturan
Instruksi Lampu Indikator:
- BERLARI: (Selalu aktif) instruksi berjalan; (Flicker): Instruksi Tidur atau Berhenti
- BERHENTI: Menghentikan atau Standby Instruksi
- Pompa bersih: Instruksi Online: Saat lampu menyala, komunikasi berhasil.
- ALARM: Alarm kesalahan VFD
- Hz: Saat lampu menyala, konten layar berjalan frekuensi.
- A: Saat lampu menyala, konten tampilan adalah arus output.
- V: Saat lampu menyala, konten layar adalah tegangan bus.
- Set bar: Ketika cahaya menjalankan frekuensi dan arus output menyala, konten tampilan adalah tekanan yang telah ditentukan sebelumnya.
- Sys Bar: Ketika cahaya arus output dan tegangan bus menyala, konten tampilan adalah tekanan yang telah ditetapkan sebelumnya.
Daftar model konverter frekuensi listrik
| Model |
Kekuatan Dinilai (KW) |
Kapasitas daya (KVA) |
Arus input (A) |
Keluaran (A) |
KW | Hp |
|---|---|---|---|---|---|---|
| 220V fase tunggal | ||||||
| PDG 10-2 SR75B | 0.75 | 1.5 | 8.2 | 4.5 | 0.75 | 1 |
| PDG 10-2 S1R5B | 1.5 | 3 | 14 | 7 | 1.5 | 2 |
| PDG 10-2 S2R2B | 2.2 | 4 | 23 | 9.6 | 2.2 | 3 |
| Tiga fase 380V | ||||||
| PDG 10-4 TR75B | 0.75 | 1.5 | 3.4 | 2.5 | 0.75 | 1 |
|
PDG 10-4 t1r5b
|
1.5 |
3 | 5.0 | 3.8 | 1.5 | 2 |
|
PDG 10-4 T2R2B
|
2.2 | 4 | 5.8 | 5.1 | 2.2 | 3 |
|
PDG 10-4 t004b/5r5p
|
4/5.5 | 5.9/8.9 |
10.5/14.6
|
9/13
|
4/5.5
|
5.5/7.5
|
|
PDG 10-4 t5r5b/7r5p
|
5.5/7.5
|
8.9/11
|
14.6/20.5
|
13/17
|
5.5/7.5
|
7.5/10
|
|
PDG 10-4 t7r5b
|
7.5
|
11
|
20.5
|
17
|
7.5
|
10 |
|
PDG 10-4 t011b/015p
|
11/15
|
17/21
|
26/35
|
25/32
|
11/15
|
15/20
|
|
PDG 10-4 t015b/018r5p
|
15/18.5
|
21/24
|
35/38.5
|
32/37
|
15/18.5
|
20/25
|
|
PDG 10-4 t018r5b/022p
|
18.5/22
|
24/30
|
38.5/46
|
37/45
|
18.5/22
|
25/30
|
|
PDG 10-4 t022b/030p
|
22/30
|
30/40
|
46.5/62
|
45/60
|
22/30
|
30/40
|
|
PDG 10-4 t030b/037p
|
30/37
|
40/57
|
62/76
|
60/75
|
30/37 | 40/50 |
|
PDG 10-4 t037b/045p
|
37/45
|
57/69
|
76/92
|
75/91
|
37/45 | 50/60 |
|
PDG 10-4 t045b/055p
|
45/55
|
69/85
|
92/113
|
91/110
|
45/55 | 60/70 |
|
PDG 10-4 t055b/075p
|
55/75
|
85/114
|
113/157
|
112/150
|
55/75 | 70/100 |
|
PDG 10-4 t075b/093p
|
75/93
|
114/134
|
157/180
|
150/170
|
75/93 | 100/125 |
|
PDG 10-4 t093b/110p
|
93/110
|
134/160
|
180/214
|
170/210
|
93/110
|
125/150
|
|
PDG 10-4 t110b/132p
|
110/132
|
160/192
|
214/256
|
210/253
|
110/132
|
150/180
|
|
PDG 10-4 t132b/160p
|
132/160
|
192/231
|
256/307
|
253/304
|
132/160
|
180/220
|
|
PDG 10-4 t160b/185p
|
160/185
|
231/245
|
307/345
|
304/340
|
160/185
|
220/250
|
|
PDG 10-4 t185b/200p
|
185/200
|
245/260
|
345/385
|
340/377
|
185/200
|
250/275
|
|
PDG 10-4 T200b/220p
|
200/220
|
260/280
|
385/430
|
377/426
|
200/220
|
275/300
|
|
PDG 10-4 t220b/250p
|
220/250
|
280/355
|
430/468
|
426/465
|
220/250
|
300/340
|
|
PDG 10-4 T250b/280p
|
250/280
|
355/396
|
468/525
|
465/520
|
250/280
|
340/380
|
|
PDG 10-4 t280b/315p
|
280/315
|
396/445
|
525/590
|
520/585
|
280/315
|
380/430
|
|
PDG 10-4 t315b/355p
|
315/355
|
445/500
|
590/665
|
585/650
|
315/355
|
430/480
|
|
PDG 10-4 t355b/400p
|
355/400
|
500/565
|
665/785
|
650/725
|
355/400
|
480/545
|
|
PDG 10-4 T400B
|
400
|
565
|
785
|
725
|
400 | 545 |
Kesalahan dan penanganan umum
Tidak ada tampilan di Power on
- Periksa apakah daya input konsisten dengan tegangan nominal drive dengan multimeter.
- Periksa apakah jembatan penyearah tiga fase utuh. Jika jembatan penyearah dipecah, silakan minta layanan.
Power Air Switch tersandung di Power on.
- Periksa apakah ada koneksi sirkuit pendek atau ground antara daya input. Jika ya, silakan hilangkan.
- Periksa apakah jembatan penyearah telah dipecah. Jika ya, silakan minta layanan.
Motor tidak berputar setelah VFD berjalan.
- Periksa apakah ada output tiga fase yang seimbang di antara U, V, W. Jika ya, periksa apakah motornya rusak atau diblokir. Jika tidak, harap konfirmasi apakah parameter motor diatur dengan benar.
- Jika ada output tetapi daya tiga fase tidak seimbang, silakan minta layanan.
- Jika tidak ada tegangan output, silakan minta layanan.
Itu tidak berhenti dalam penggunaan air.
- Periksa apakah tekanan umpan balik yang ditampilkan pada papan VFD tidak kurang dari tekanan yang ditetapkan. Jika tekanan umpan balik kurang dari tekanan yang diatur, silakan periksaApakah kisaran sensor tekanan diatur dengan benar, apakah pompa berputarTerbalik, apakah ada udara dan apakah inlet diblokir oleh serba.
- Jika nilai umpan balik berubah bolak -balik di sekitar nilai yang ditetapkan, hentikan VFD secara manual dan periksa apakah tekanan terus menurun atau tidak. Jika ya, itu perlu mengubah katup periksa.
Itu tidak bisa tidur dalam sejumlah kecil penggunaan air atau kebocoran
- Jika tidak dapat tidur atau waktu tidur terlalu lama, harap kurangi nilai f 0. 04 dengan benar.
- Jika mulai dan sering berhenti, harap tingkatkan nilai f 0. 04 dengan benar
Tidak bisa berhenti untuk membuat perlindungan dalam kekurangan air.
- Sakelar perlindungan kekurangan air (f4. 00) tidak diaktifkan.
- Nilai ambang deteksi kekurangan air (F4.01) diatur terlalu rendah.
- Persentase saat ini dari deteksi kekurangan air (F4.04) ditetapkan terlalu rendah.
Tindakan pencegahan keselamatan konverter frekuensi listrik
Instalasi ekonverter frekuensi lektrik
- Saat memasang atau memindahkan inverter, silakan pegang bagian bawah produk alih -alih hanya menahan cangkang luar untuk mencegah inverter hancur atau rusak.

- Inverter harus dijauhkan dari benda yang mudah terbakar dan meledak dan sumber panas, dan dipasang pada penghambat api seperti logam.
- Ketika inverter dipasang di lemari listrik atau selungkup lainnya, kipas atau peralatan pendingin lainnya harus dipasang di kabinet, dan ventilasi harus diatur untuk memastikan bahwa suhu sekitar di bawah 40 derajat. Kalau tidak, inverter mungkin rusak karena suhu sekitar yang terlalu tinggi.
Kabelkonverter frekuensi listrik
- Pengkabelan harus diselesaikan oleh insinyur listrik profesional yang memenuhi syarat, jika tidak, mungkin ada sengatan listrik atau kerusakan pada inverter.
- Pastikan catu daya terputus sebelum mulai kabel, jika tidak dapat menyebabkan sengatan listrik atau kebakaran.
- Terminal pentanahan harus diandalkan, jika tidak, perumahan inverter berbahaya untuk diberi energi.
- Jangan menyentuh terminal sirkuit utama, dan kabel terminal sirkuit utama inverter tidak boleh menghubungi rumah, jika tidak dapat menyebabkan sengatan listrik.
- Sebelum kabel, konfirmasikan bahwa tegangan pengenal dan jumlah fase inverter konsisten dengan tegangan daya input dan nomor fase, jika tidak dapat menyebabkan kebakaran atau cedera pribadi.
- Catu daya input AC tidak dapat dihubungkan ke terminal output inverter u, v, dan w, jika tidak itu akan menyebabkan kerusakan pada inverter dan tidak akan memenuhi syarat untuk layanan garansi.
- Inverter tidak dapat dikenakan uji tegangan tahan, jika tidak itu akan menyebabkan kerusakan pada inverter.
- Pengkabelan terminal sirkuit utama dan kabel sirkuit kontrol inverter harus disesuaikan secara terpisah atau dilintasi secara vertikal, jika tidak, sinyal kontrol akan terganggu.
- Kabel kabel terminal sirkuit utama harus menggunakan hidung kawat dengan lengan isolasi.
- Ketika panjang kabel antara inverter dan motor melebihi 50 meter, disarankan untuk menggunakan reaktor output untuk melindungi inverter dan motor.
Tag populer: Konverter Frekuensi Listrik, Produsen Konverter Frekuensi Listrik China, Pemasok, Pabrik